Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
---|---|
Type: | Patient Monitor |
Group: | Pediatric and Adult |
High-Brightness TFT LED: | 12.1 Inches |
Printer: | Built-in Thermal Printer |
Power Supply: | AC100-240V, 50/60Hz, Power≤60W |
Customization: |
---|
Suppliers with verified business licenses
Measurement range | -50-360mmHg | ||||
Channel | 2 channels | ||||
Pressure transducer | Sensitive :5 uV/V mmHg Impedance range :300-3000 Ω |
||||
Pressure names | ART, PA, CVP, RAP, LAP, ICP, P1, P2 | ||||
Alarm range | -10-300 mmHg | ||||
PR from IBP | Range & Accuracy: | 25-200bpm ±1bpm or ±1bpm which is greater 201-350bpm ±2% |
|||
Resolution : | 1bpm | ||||
Depth of Anesthesia (BIS) | |||||
EEG sensitivity | +/- 475μV | ||||
Noise | < 2uVp-p (1-150 Hz) | ||||
CMRR | > 100 dB | ||||
Input impedance | > 50mohm | ||||
Sample rate | 1024 samples/s, 16 bits |
Index and display update | 0-100, filter 1-47 Hz, 1 sec. display update |
EEG waveform | ± 500 µV scaleable, filter 1-30 Hz, 3 sec. window length. |
ESR | 0-100% |
EMG 0-100 arbitrary unit | Curve and bar |
Index trend | 5 min and 60 min |
Digital output | Wireless BT interface (RFCOMM) 10 meters range |
Alarms | IoC high and low user selectable limits |
Artifact rejection | Automatic: user can disable. |
Sensor impedance range | 0 - 14kohm |
EtCO2 (Main-stream / Side-stream ) | |
Measurement range | 0-150mmHg |
Accuracy | ±2mmHg(0-40mmHg) ±5% of reading(41-76mmHg) ±10% of reading (77-99mmHg) |
Resolution | 1mmHg |
Sampling rate | 70m1/min 100m1/min |
Sampling rate accuracy | 0.15 or 15m1/min |
Start-up time |
30 Sec. the module enters the warming up status after the start up. 1 minute later, it enters the ready-to-measure status. |
Respiration rate | 3-150 rpm |
Respiration rate accuracy | ±2BrPM (0-70BrPM) ±5BrPM (>70BrPM) |
Response time |
When measured with a neonatal water trap and a 2.5 m-long neonatal sampling line: < 3.5 s @ 100 ml/min <4 s @ 70 ml/min |
When measured with an adult water trap and a 2.5 m-long adult sampling line: <5.5 s @ 100 ml/min <7 s @ 70 ml/min |
|
Delay time |
When measured with a neonatal water trap and a 2.5m-long neonatal sampling line: <3 s @ 100 ml/min <3.5 s @ 70 ml/min |
When measured with an adult water trap and a 2.5m-long adult sampling line: <5 s @ 100 ml/min <6.5 s @ 70 ml/min |
Zhangjiagang Roc Medical Technology Co.,Ltd is located in Zhangjiagang City, Jiangsu Province, China.
Till now,we are working to research and develop Operating room equipments, Medical sterilizer, hospital beds, hospital furnitures and other medical electronic products.
Our products were sold to more than 200 countries.
Our after-sales team will resolve your problems in time within 24hours.
Learn to be a decent person before learning how to do things.
In Good Faith Cooperation,Sincerely make friends,To create a win-win situation.
This is the cornerstone of our eternal achievement.
Suppliers with verified business licenses