Body 8.0 inch high-brightness TFT LED Support display maximum 8 waveforms Support 6 channel ECG waveform display simultaneously Optional touch screen |
Central System Optional: supporting wired or wireless connection to the central monitoring station. |
Stroage Support storage of 168 hours trend table and graph review 100 minutes waveform review 500 groups NIBP review 100 hours of parameter alarm events review and associated parameters |
Alarm Three-level acousto-optic alarm Sensor-off alarm Paper out alarm Support alarm review Support alarm pause |
Printer Built-in high-speed 50 mm thermal printer (Brand: SEIKO, Japan) |
Operating System Multi-display mode to meet different clinical requirement, including standard interface, big font, OxyCRG, trend graph, NIBP review and full leads ECG interface. NIBP self-test mode: including overpressure test, static pressure test and air leakage test. 15 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection Drug calculation and titration table Support multi-language display Support online software upgrading by net |
Interface Transducer socket ECG SPO2 NIBP TEMP 1 TEMP 2 / Mainstream EtCO2 |
LAN / Central monitor system interface The LAN port is for connecting the monitor to a central monitor system network. Input device interface Knob (Standard) Touch screen (optional) |
Dimension and Weight - Dimension: 175mm*210mm*80mm - Weight:1.35kg(excluding accessories) Power Supply - Adapter: Output 13-20V DC, 5A - Voltage: AC100~240V, 50/60HZ Display - 8" color TFT LED - Resolution: 800*600 pixels Battery (Pluggable) - Type: Rechargeable lithium battery 14.8V/2200mAh - Charge Cycle: ≥500 times - Working time: 5.5 hours Recorder (Option) - Method: Thermal printer - Paper width: 50 mm (1.97 in) - Printing speed: 25/ 50 mm/s - Trace: Max. 2 tracks - Recording way: Real-time Recording, Alarm Recording Alarm - Level: Low, medium and high - Indication: Auditory and visual - Alarm volume adjustable - Alarm pause time: 1min, 2min - Parameter alarm type: Latch/ Unlatch Input Device - Touch screen (option) - Knob (Standard) - Keypad input (Standard) System Output & Extensible Interface - Ethernet Network: 1 standard RJ45 socket Operating Environment - Temperature: 5 ~ 40 ºC - Humidity: 15% ~ 80% (non-condensing) - Atmosphere pressure: 86 KPa ~ 110 KPa ST Measurement - Range: -2.0 ~ +2.0 mV - Accuracy: -0.8mV ~ +0.8mV: ±0.02mV or ±10%, whichever is greater - Other range: unspecified Respiration - Method: Impedance between RA-LL, - Gain: ×0.25, ×0.50, ×1, ×2, - Respiration Rate: 0bpm, 0 ~ 150 BrPM - Sweep speed: 6.25 mm/s, 12.5 mm/s, 25mm/s - Resolution: 1 BrPM - Accuracy: ±2 bpm or ±2%, whichever is greater - Apnea Alarm: 10 ~ 40 s NIBP - Method: Oscillometric - Measure mode: Manual, Auto, STAT - Measure Interval in AUTO Mode 1~480 min - STAT mode cycle time: Keep 5 minutes, at 5 seconds interval - Measure and Alarm Range: Adult SYS: 40 ~ 270 mmHg DIA: 10 ~ 215mmHg MEAN: 20 ~ 235 mmHg Pediatric: : SYS: 40 ~ 200 mmHg DIA: 10 ~ 150mmHg MEAN: 20 ~ 165 mmHg Neonate: SYS: 40 ~ 135 mmHg DIA: 10 ~ 100mmHg MEAN: 20 ~ 110 mmHg - Static pressure accuracy: ±3mmHg - Resolution: 1mmHg - Accuracy: Maximum Mean error ±5mmHg Maximum Standard deviation ≤8mmHg - Over pressure Protection: Dual protection via software & hardware |
Transportation and Storage Environment - Temperature: -20~50 ºC - Humidity: 10%~90% (non-condensing) - Atmosphere pressure: 86 KPa ~ 110 KPa Safety - IEC60601-1 Approved, CE marking according to MDD93/42/EEC - With reference to RoHS Directive 2011/65/EU recasting Trend & Reviewing - Trend: 168 hours - NIBP measurement reviewing: 500 groups - Waveform review: 100 minutes - Alarm event: 100hours of parameter alarms events and associated parameter ECG - Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V - Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2), - Sweep speed: 6.25 mm/s12.5 mm/s, 25 mm/s, 50 mm/s - ECG signal range: ±6 mV - Accuracy: ±1bpm/ ±1%, whichever is greater - Resolution: 1 bpm - Leakage Current < 10 μA - Input impedance: > 5.0Mohm - CMRR: Diagnostic Mode >90 dB; Monitor Mode>100dB Surgery Mode>100dB - Baseline Recovery: ≤ 5s after defibrillation (Monitor or Surgery mode) - Bandwidth: Surgery 1 ~ 20Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz - Against electrosurgical interference and defibrillation - Indication of Electrode Separation: Every electrode (exclusive of RL) Heart Rate - Measure range: Adult 0bpm; 15 ~ 300 bpm Pediatric: and Neonate: 0bpm; 15 ~ 450 bpm - Resolution: 1 bpm - Accuracy: ± 1% or ± 1bpm, whichever is greater SpO2 (Analog Technic) - Measurement Range: 0 ~ 100 % - Resolution: 1 % - Accuracy: ±2% (70% ~ 100%) Unspecified (0 ~ 69%) Pulse Rate - Measuring and Alarm Range: 20~450bmp - Accuracy: ±3% - Resolution: 1bpm EtCO2 (Mainstream) (Option) - Measure method: Non-dispersive infrared (NDIR) - Measure Range: 0 ~19.7% (0 ~ 150 mmHg) 0 ~ 20 kPa - Resolution: 0.1 mmHg - CO2 Accuracy: 0 ~ 40 mmHg, ±2 mmHg 41 ~ 70 mmHg, ±5% of reading 71 ~ 100 mmHg, ±8% of reading 101~ 150 mmHg, ±10% of reading at 760 mmHg, ambient temperature of 25ºC) - Respiratory Rate: Range: 3 ~150 BrPM Accuracy: ±1 bpm Temperature - Technique: Thermistor probe (2.25K) - Channel: Dual-channel, provide T1; T2; ΔT - Measuring and Alarm Range: 0.0 ºC~ 50 ºC (32ºF~ 122ºF) - Unit: Celsius (ºC), Fahrenheit ( ºF) - Resolution: 0.1ºCor 1ºF - Accuracy: ±0.1ºC(exclusive probe) |
Zhangjiagang Roc Medical Technology Co.,Ltd is located in Zhangjiagang City, Jiangsu Province, China.
Till now,we are working to research and develop Operating room equipments, Medical sterilizer, hospital beds, hospital furnitures and other medical electronic products.
Our products were sold to more than 200 countries.
Our after-sales team will resolve your problems in time within 24hours.
Learn to be a decent person before learning how to do things.
In Good Faith Cooperation,Sincerely make friends,To create a win-win situation.
This is the cornerstone of our eternal achievement.