Customization: | Available |
---|---|
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
Type: | Patient Monitor |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Standard Configuration | 12.1-inch LED, 3/5 Lead ECG, NIBP, SpO2, Pulse Rate, Temperature, Respiration |
Optional Configuration | 2-Temperature, 1/2 IBP, EtCO2, Masimo SpO2, Nellcor SpO2, Bed View |
Optional Accessories | Touch Screen, Printer, Central Monitoring Station, Neo/Ped Accessories, Wall-mounting, Trolley |
Dimension and Weight - Dimension: 298mm*272mm*122mm - Weight: 2.5 kg (excluding accessories) Power Supply - Voltage: AC100~240V, 50/60HZ, Power≤60W Display - 12.1" color TFT LED resolution: 800*600 pixels Battery - Type: Rechargeable lithium battery 14.8V/2200mAh - Charge Cycle: ≥500 times - Working time: 3.5 hours Recorder (Option) - Method: Thermal printer - Paper width: 50 mm (1.97 in) - Printing speed: 12.5/25/ 50 mm/s - Trace: Max. 3 tracks - Recording way: Real-time Recording, Review Printing, Periodic Recording, Alarm Recording Alarm - Level: Low, medium and high - Indication: Auditory and visual - Alarm volume adjustable - Alarm pause time: 2min - Parameter alarm type: Latch/ Unlatch Input Device - Standard: Knob /Keypress - Option: Touch screen System Output & Extensible Interface - Ethernet Network: standard RJ45 socket * 1pc - USB Port: 1pc Operating Environment - Temperature: 5 ~ 40 ºC - Humidity: 15% ~ 90% (non-condensing) - Atmosphere pressure: 86 KPa ~ 110 KPa Transportation and Storage - Temperature: -20~50 ºC - Humidity: 10%~90% (non-condensing) - Atmosphere pressure: 86 KPa ~ 110 KPa Safety - IEC60601-1 Approved, CE marking according to MDD93/42/EEC - With reference to RoHS Directive 2011/65/EU recasting Trend & Reviewing - Trend: 720 hours - ARR events: 128 groups of ARR events and associated waveform - NIBP measurement reviewing: 1000 groups - Waveform review: 2 hours - Alarm event: 200 alarms events review SpO2 - Measurement Range: 0 ~ 100 % - Resolution: 1 % - Accuracy: ±2% (70% ~ 100%) Unspecified (0% ~ 69%) - Support Pitch tone and multi-level volume - User-selectable waveform speed: 12.5, 25 mm/s - PI range (Option):0.075%-20% Pulse Rate - Measuring and Alarm Range: 20~250bpm - Accuracy: ±3 bpm - Resolution: 1bpm |
Respiration - Method: Impedance between RA-LL, RA-LA - Gain: ×0.25, ×0.50, ×1, ×2, ×4 - Respiration Rate: Adult 0 ~ 120 BrPM Neonatal / Pediatric 0 ~ 150 BrPM - Sweep speed: 6.25 mm/s, 12.5 mm/s, 25mm/s - Resolution: 1 BrPM - Accuracy: ±2BrPM or ±2% whichever is greater (7~150BrPM) Unspecified (0%~ 6BrPM) - Apnea Alarm: 10 ~ 40 s Temperature - Technique: Thermistor probe (2.25K) - Channel: Dual-channel, provide T1; T2; ΔT - Measuring and Alarm Range: 0.0 ºC~ 50 ºC (32ºF~ 122ºF) - Unit: Celsius (ºC), Fahrenheit ( ºF) - Resolution: 0.1ºCor 1ºF - Accuracy: no sensor ± 0.1ºC(25ºC - 45ºC) ,± 0.2ºC(other) include sensor ± 0.2ºC(32ºC - 42ºC)± 0.3ºC(other) ECG - Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V - Protection: Breakdown Voltage 4000VAC 50/60Hz; Defibrillator proof - Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2) - Sweep speed: 12.5mm/s, 25mm/s, 50mm/s - ECG signal range: ±5 mV p-p - Accuracy: ±1% - Resolution: 1 bpm - Leakage Current < 10 μA - Baseline Recovery: ≤ 3s after defibrillation - Bandwidth: Surgery 1 ~ 20Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz - Indication of Electrode Separation: Every electrode (exclusive of RL) Heart Rate - Measure range: Adult: 15 ~ 300 bpm Neo/Ped: 15 ~ 350 bpm - Resolution: 1 bpm - Accuracy: ± 1% ST Measurement - Range: -2.0 ~ +2.0 mV - Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater, other range: unspecified NIBP - Method: Oscillometric - Measure mode: Manual, Auto, STAT - Measure Interval in AUTO Mode 1,2,3,4,5,10,15,30,60,90,120,180,240,480 min - STAT mode cycle time: 5 minutes - Measure and Alarm Range: Adult: SYS: 40 ~ 280 mmHg DIA: 10 ~ 220 mmHg MEAN: 20 ~ 240 mmHg Pediatric: SYS: 40 ~ 220 mmHg DIA: 10 ~ 160 mmHg MEAN: 20 ~ 170 mmHg Neonate: SYS: 30 ~ 135 mmHg DIA: 10 ~ 110 mmHg |
MEAN: 20 ~ 110 mmHg - Static pressure accuracy: ±3mmHg - Resolution: 1mmHg - Accuracy: Maximum Mean error ±5mmHg Maximum Standard deviation ≤8mmHg - Over pressure Protection: Dual protection EtCO2 (Mainstream/ Sidestream) (Option) - Measure method: Non-dispersive infrared (NDIR) - Measure Range: 0 ~19.7% (0 ~ 150 mmHg) 0 ~ 20 kPa - Resolution: 0.1 mmHg - CO2 Accuracy: 0 ~ 40 mmHg, ±2 mmHg 41 ~ 70 mmHg, ±5% of reading 71 ~ 100 mmHg, ±8% of reading 101~ 150 mmHg, ±10% of reading at 760 mmHg, ambient temperature of 25ºC) - Respiratory Rate: Range: 3 ~150 BrPM Accuracy: ±1 bpm EtCO2 (Micro-stream) (Option) - Measure method: Non-dispersive infrared (NDIR) - Measure Range: 0 ~19.7% (0 ~150 mmHg) 0 ~ 20 kPa - Sample Rate: 50 mL/min ±10mL/min - Resolution: 0.1 mmHg (0 ~ 50 mmHg) 0.25 mmHg (50 ~ 114 mmHg) - CO2 Accuracy: 0 ~ 40 mmHg, ±2 mmHg 41 ~ 70 mmHg, ±5% of reading 71 ~ 100 mmHg, ±8% of reading 101~ 150 mmHg, ±10% of reading at 760 mmHg, ambient temperature of 35ºC) - Respiratory Rate: Range: 3 ~120 BrPM Accuracy: ±1 bpm IBP (Option) - Max Channel: 2 - Measurement way: Thermal resistance way - Press Sensor: Sensitivity 5 uV/V/mmHg, ±2% Impedance 300 to 3000Ω - Resolution: 1 mmHg - Unit: mmKg, kPa, cmH2O - Transducer sites: Arterial Pressure (ART) Pulmonary Arterial (PA) Left Arterial (LAP) Right Arterial (RAP) Central Venous Pressure (CVP) Intracranial Pressure (ICP) P1/ P2 - Measuring and alarm range: ART 0 ~ +350mmHg PA -10 ~ +120 mmHg CVP/ RAP/ LAP/ ICP -10 ~ +40 mmHg P1/ P2 -50 ~ +350mmHg - Accuracy: Static: ±1mmHg or ±2%, whichever is greater (exclusive of transducer) ±4mmHg or ±4%, whichever is greater (inclusive of transducer) Dynamic: ±4mmHg or ±4%, whichever is greater * Specifications subject to change without prior notice |
Zhangjiagang Roc Medical Technology Co.,Ltd is located in Zhangjiagang City, Jiangsu Province, China.
Till now,we are working to research and develop Operating room equipments, Medical sterilizer, hospital beds, hospital furnitures and other medical electronic products.
Our products were sold to more than 200 countries.
Our after-sales team will resolve your problems in time within 24hours.
Learn to be a decent person before learning how to do things.
In Good Faith Cooperation,Sincerely make friends,To create a win-win situation.
This is the cornerstone of our eternal achievement.