Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | X Ray Equipment |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Generator Type:High Frequency Inverter 80kHz
Input Power: Single phase 220VAC, 50/60Hz
Radiographic Ratings:Large Focal Point 20-35kV/10-510mAs
Small Focal Point 20-35kV/10-100mAs
Power Rating:6kW
Focal Spot Size: Dual Focus 0.2 / 0.4mm
Target Material:Molybdenum (Mo)
Port Material:Beryllium (Be)
Anode Heat Storage: 100KJ
Anode Cooling:Air cooling
Filtration: Mo(0.03mm),Al(0.5mm)
X-ray Generator
Complete solid-state high-frequency high-voltage generator.
Generator Type:High Frequency Inverter 80kHz
Input Power:Single phase 220VAC, 50/60Hz
Radiographic Ratings:Large Focal Point 20-35kV/10-510mAs
Small Focal Point 20-35kV/10-100mAs
Power Rating:6kW
X-ray Tube
Model:China Hangzhou LR01
Focal Spot Size:Dual Focus 0.2/0.4mm
TargetMaterial:Molybdenum (Mo)
Port Material:Beryllium (Be)
High-speed anode drive: 2800 /1000rpm
Target angle:12°/12°
AnodeHeat Storage:100KJ(150KHU)
Anode Cooling:Air cooling
Filtration:Mo(0.03mm),Al(0.5mm)
Radiographic Stand
C-ARM:VerticalMovement:590mm
Center of electric rotating C-arm,automatic return function by one key
Rotations Degree:-90°~+90°
Automatically released after the exposure pressure settings display
Compression flexible stepless speed.
Max. pressure: 200N
Max. travel: 150mm
SID:650mm
Cassette Image Receptor
18×24cm(24cmX30cm optional)
BuckyDevice:18×24cmBucky drive mechanism,(24cmX30cm optional)
Grid Ratio:5:1 ,30 Line/cm
2) Italian IAE Tube
X-ray Generator
Complete solid-state high-frequency high-voltage generator.
Generator Type:High Frequency Inverter 80kHz
Input Power:Single phase 220VAC, 50/60Hz
Radiographic Ratings:Large Focal Point 20-35kV/10-510mAs
Small Focal Point 20-35kV/10-100mAs
Power Rating:6kW
X-ray Tube
Model:IAE C339V
Focal Spot Size:Dual Focus 0.1/0.3mm
Target Material:Molybdenum (Mo)
Port Material:Beryllium (Be)
High-speed anode drive: 2800 /1000rpm
Target angle:10°/16°
AnodeHeat Storage:210kJ (300kHU)
Anode Cooling:Air cooling
Filtration:Mo(0.03mm),Al(0.5mm)
Radiographic Stand
C-ARM:Vertical Movement:590mm
Center of electric rotating C-arm, automatic return function by one key
Rotations Deg:+90°~-90°
Automatically released after the exposure pressure settings display
Compression flexible stepless speed.
Max. pressure: 200N
Max. travel: 150mm
SID:650mm
Cassette Image Receptor
18×24cm
Bucky Device:18×24cm Bucky drive mechanism
Grid Ratio:5:1 ,30 Line/cm
3) USA VARIAN Tube
X-ray Generator
Complete solid-state high-frequency high-voltage generator.
Generator Type:High Frequency Inverter80kHz
Input Power:Single phase 220VAC, 50/60Hz
Radiographic Ratings:Large Focal Point 20-35kV/10-510mAs
Small Focal Point 20-35kV/10-100mAs
Power Rating:6kW
X-ray Tube
Model:VARIAN B115
Focal Spot Size:Dual Focus 0.1/0.3mm
TargetMaterial:Molybdenum (Mo)
Port Material:Beryllium (Be)
High-speed anode drive: 2800 /1000rpm
Target angle:10°/16°
AnodeHeat Storage:210kJ (300kHU)
Anode Cooling:Air cooling
Filtration:Mo(0.03mm),Al(0.5mm)
Radiographic Stand
C-ARM:VerticalMovement:590mm
Center of electric rotating C-arm,automatic return function by one key
Rotations Deg:+90°~-90°
Automatically released after the exposure pressure settings display
Compression flexible stepless speed.
Max. pressure: 200N
Max. travel: 150mm
SID:650mm
Factory price Hospital Medical High Frequency HF 6kW 510mAs Digital Radiography Mammography System X Ray