Type: | Anaesthesia Machine |
---|---|
Group: | All |
LCD Display: | With LCD Display |
OEM&ODM: | Available |
Factory Location: | 2 Hours From Shanghai |
Sample: | Available |
Customization: |
---|
Suppliers with verified business licenses
Ventilation modes
|
Manual, (V-CMV)IPPV, (P-CMV)PCV, (P-S1MV), (V-S1MV), PSV, PRVC
|
||
Mian ventilator parameter
|
Tidal volume(Vt)
|
0, 10 mL ~ 1500 mL
|
|
Frequence(Freq)
|
4bpm ~ 100 bpm
|
||
I/E
|
4: 1~1: 10
|
||
Ventilator parameter
|
PEEP
|
0CMH2O ~ 30 CMH2O
|
|
Rapid oxygen supply
|
35L/min-75L/min
|
||
Pressure trigger
|
-1CMH2O~-20CMH2O
|
||
Flow trigger
|
0.3 L/min, 1L/min~15L/min
|
||
Pressure support
|
3CMH2O~50CMH2O
|
||
Pressure limit
|
10CMH2O~100CMH2O
|
||
Inspiration apnea
|
OFF, 5%~60%
|
||
Inspiration time
|
0.2s~5s
|
||
Trigger
|
5%~95%
|
||
SIMV frequency
|
4bpm~60bpm
|
||
Rise time
|
0s~2s
|
||
Monitored Parameters
|
Frequence(Freq)
|
0bpm~120bpm
|
|
Tidal volume(Vt)
|
0mL~2500mL
|
||
Minute volume
|
0L/min~100L/min
|
||
Oxygen concentration
|
15 % ~ 100 %
|
||
Airway pressure
|
-20CMH2O~100CMH2O
|
||
Inspiration platform pressure
|
0CMH2O~100CMH2O
|
||
PEEP
|
0CMH2O~70CMH2O
|
||
I: E
|
4: 1~1: 10
|
||
|
P-T(pressure - time)
|
||
F-T(flow - time)
|
|||
P-V loop (pressure - volumeloop)
|
|||
V-T(volume - time )
|
|||
Lung function loop
|
|||
ETCO2-Time
|
|
||
|
VT UPPER LIMIT
|
5mL~2000mL
|
|
VT LOWER LIMIT
|
0mL~1595mL
|
||
MV upper limit
|
0.1L/min~100L/min
|
||
MV lower limit
|
0.0L/min~99.9L/min
|
||
Respiration frequency upper limit
|
2bpm~100bpm
|
||
Respiration frequency lower limit
|
0bpm~98 bpm
|
||
FIO2 upper limit
|
20%~100%
|
||
FIO2 lower limit
|
18%~98%
|
||
Airway pressure upper limit
|
2CMH2O~100CMH2O
|
||
Airway pressure lower limit
|
0CMH2O~98CMH2O
|
||
Apnea
|
20s~40s
|
||
Oxygen concentration never lower than 25% when N2O start
|
|||
|
Automatic leakage compensation testing.
|
||
Patient circuit leakage compensation and automatic compliance compensation.
|
|||
Patient monitor and AG monitor can be equipped.
|
|||
Patient monitor and AG monitor can be equipped.
|
|||
Manual ventilator, mechanical ventilation and standby.
|
|||
Waveform: P-T, F-T, V-T, Lung function loop, ETCO2, Anesthesia gas, oxygen concentration, N2O concentration.
|
|||
Self-testing visible
|
|||
Alarming visible
|
|||
ACGO function
|
|||
Parking Size
|
Wooden case packing size: 870*1000*1600mm, G. W: 235KG, N. W: 160KG,
Including anesthesia ventilator, not including vaporizer.
|
15" TFT LCD touch screen displays anesthesia machine(Manual, (V-CMV)IPPV, (P-CMV)PCV, (P-S1MV), (V-S1MV), PSV, PRVC) with ETCO2, O2 concentration detection
Suppliers with verified business licenses